Gas pipe length, a 120-volt outlet and permit rules decide whether the hookup stays under $800 or climbs past $1,500.

Save to Pinterest

We may earn a commission when you buy through links on this page. It never changes what we recommend. Learn more

Gas dryer in a laundry room with a shutoff valve and flexible connector visible behind it
Photo: Point3D Commercial Imaging Ltd. on Unsplash

The short answer

Converting from electric to gas means buying a gas dryer and adding a gas line. Most hookups cost $500 to $1,500 for pipe, valve, connector, permit and leak test, with short runs near $250 to $800 and long runs through finished walls $1,500 to $3,500 or more. The dryer costs extra and plugs into a standard 120-volt outlet.

Typical cost
$250 to $3,500 installed, not counting the dryer
Time needed
Half a day to two days
Skill level
Hire a pro

Key points

  • Gas pipe length is the biggest swing factor: a 10-foot run often lands near $300 to $800, while a 40-foot run can reach $800 to $1,800.
  • A gas dryer plugs into a standard 120-volt outlet, so your old 240-volt outlet goes unused and should be shut off and covered.
  • Install a new dryer-rated flexible gas connector and confirm the vent is rigid or semi-rigid metal that exhausts outdoors.
  • New gas piping and electrical work should go to a licensed plumber or electrician, and many jurisdictions require a permit and inspection.
  • Get itemized written quotes that state the run length, permit fees and leak testing so you can compare them fairly.
In this guide
  1. What does an electric to gas dryer conversion involve?
  2. What does each hookup piece cost?
  3. How much does gas line run length change the price?
  4. Will your 240-volt outlet work for a gas dryer?
  5. What pushes the price up or down?
  6. How can you cut the bill without cutting safety?
  7. Can you DIY it or do you need a licensed pro?

Most of the bill is gas pipe, not wiring. A gas dryer runs its drum and controls on a standard 120-volt outlet, so the 240-volt circuit your electric dryer uses isn't part of the new hookup. You're paying for a gas line that reaches the laundry spot, a shutoff valve, a new connector, a permit in many towns, and a dryer vent that can handle combustion exhaust. The dryer is a separate purchase, and a gas model typically runs roughly $700 to $1,500 depending on brand and features.

What does an electric to gas dryer conversion involve?

An electric to gas dryer conversion means replacing the appliance and adding a gas supply, a 120-volt outlet and a vent that is safe for combustion exhaust.

You can't convert the electric dryer you own. Its heating element has no gas equivalent, so the old unit goes and a gas model takes its place. The work usually runs in this order:

  1. Confirm gas service reaches the house and find the nearest branch pipe or the meter.
  2. Have a licensed plumber run pipe to the laundry spot and finish it with a gas shutoff valve and the fitting size your dryer's manual calls for, often a 3/8-inch flare.
  3. Make sure a grounded 120-volt outlet sits within reach of the dryer's cord, which is typically only a few feet long.
  4. Inspect the dryer vent and replace anything that is vinyl, foil or crushed.
  5. Pressure test the new pipe, leak check every joint, and pass inspection where required.
  6. Connect the dryer with a new flexible gas connector.

The vent step trips people up. A gas dryer exhausts combustion byproducts, including carbon monoxide, so the duct has to stay intact and end outdoors. Check your dryer's manual for its maximum vent length, and replace vinyl or foil duct no matter what.

What does each hookup piece cost?

Most gas dryer hookups land between $500 and $1,500 once you add the pipe, valve, connector, permit and any outlet or vent work, with the dryer priced separately.

ItemMaterialsLaborTypical total
Gas shutoff valve and stub-out at the dryer$20 to $60$100 to $250$120 to $310
Gas pipe, per foot$5 to $10$10 to $15$15 to $25 per foot
Dryer-rated flexible gas connector$15 to $40$0 to $75$15 to $115
Pressure test and leak checkMinimal$0 to $150$0 to $150 (often bundled)
Permit and inspectionNoneFee only$50 to $250
New 120-volt outlet, if none is nearby$15 to $50$130 to $350$150 to $400
Dryer vent check or replacement$20 to $100$80 to $250$100 to $350
Disconnect electric dryer and cover the 240-volt outlet$0 to $10$0 to $100$0 to $110

Rigid black iron pipe is the traditional material, and corrugated stainless steel tubing is common where local code allows it. Permit fees vary widely by city. Many plumbers also set a minimum charge, often somewhere around $150 to $400, so a very short run costs more than the per-foot math suggests. Big metro areas sit at the high end of every range here.

How much does gas line run length change the price?

Run length is the largest variable: a 10-foot run might total $300 to $800, a 40-foot run often costs $800 to $1,800, and longer or harder routes climb from there.

ScenarioTypical total (valve, pipe, test, permit)
10 feet from a nearby branch pipe$300 to $800
25 feet, mostly exposed basement or garage$550 to $1,200
40 feet, some drilling through framing$800 to $1,800
From the meter through finished walls or ceilings$1,500 to $3,500 or more

For a long run, have the plumber measure on site before you trust any estimate. Every elbow, wall penetration and finished surface adds labor. The pipe also has to be sized for the combined load of every appliance on that branch. Gas dryers often draw somewhere around 20,000 to 30,000 BTU per hour, so check the nameplate and have the plumber confirm the existing line can carry it alongside your furnace, water heater and range.

Trenching a line outdoors is a different job entirely. Call 811 before anyone digs so buried utilities get marked.

Will your 240-volt outlet work for a gas dryer?

No, a gas dryer doesn't use a 240-volt outlet, so your existing one has no job in the new setup.

Gas models need a grounded 120-volt outlet, usually on a 15-amp or 20-amp circuit, for the motor, controls and igniter. Check the installation manual for the exact requirement. If a standard outlet already sits behind or beside the dryer, this step costs nothing. If not, an electrician typically charges $150 to $400 to add one, depending on how close the nearest circuit is.

Never plug a gas dryer into a 240-volt receptacle, and don't use an adapter or swap cords to make it fit. Switch off the old double-pole breaker, label it, and put a blank cover on the receptacle. Have an electrician do this if you aren't comfortable working at the panel. Leaving the circuit in place may help resale, since the next owner could want an electric dryer, which usually needs 240 volts.

What pushes the price up or down?

Distance, access, existing pipe and local permit rules move the price most, and a ready-made gas stub-out pulls it down fast.

Costs go up when:

  • The run is long or crosses finished walls, ceilings or a slab.
  • The existing gas line is undersized and needs upgrading.
  • Corrugated stainless steel tubing needs bonding, which some codes require.
  • The laundry area is on an upper floor, which complicates routing.
  • The dryer vent is long, flexible or damaged and must be replaced.
  • You live in a high-cost metro area or need an after-hours call.

Costs come down when a capped gas stub already sits in the laundry area, when the dryer will go near the water heater or furnace, or when the plumber is already on site for other work. A previous gas dryer, or a gas range on the other side of the wall, often means the heavy lifting is done.

If your home runs on propane, the dryer needs a propane conversion kit installed by a qualified technician. Some dryers ship with one. Check the manual before you buy.

How can you cut the bill without cutting safety?

Get itemized quotes, choose the dryer location with gas in mind, and prep the space yourself, but never trade away leak testing, permits or a new connector.

  • Compare three written quotes. Each should state the pipe length, valve, test, permit fee and any outlet or vent work.
  • Pick the spot before buying. A location within 10 feet of an existing branch pipe is usually the cheapest layout.
  • Bundle jobs. Gas range, water heater or pipe repairs in the same visit spread out the minimum charge.
  • Reuse a good vent. A short, clean, rigid metal duct that exits outdoors can stay.
  • Ask your gas utility about rebates. Some offer them for efficient gas appliances, but programs vary by area.

Compare running costs before you commit, since the payoff depends on local gas and electricity rates. The U.S. Department of Energy's Energy Saver site has general guidance on dryer efficiency and operating costs, and ENERGY STAR lists certified clothes dryers if you want to compare models.

Can you DIY it or do you need a licensed pro?

A homeowner can usually handle the dryer-side tasks, but new gas piping and electrical work belong to a licensed plumber or electrician, and the rules vary by state and city.

TaskDIY?Who should do it
Moving the old dryer, clearing the spaceYesYou
Replacing the vent ductUsuallyYou or an installer
Connecting the dryer to an existing valve with a new connectorSometimes, depending on local rulesYou or a licensed plumber
Running new gas pipe and setting the valveRarely allowed or advisableLicensed plumber, with permit
Pressure test and inspectionNoPlumber and local inspector
New 120-volt outlet or breaker changesNo for most peopleLicensed electrician, with permit where required

We'd hire a licensed plumber for everything on the gas side and do the prep and vent work yourself. A poorly tested joint can leak slowly, and insurers and inspectors may care who did the work. Some areas let owners pull a permit for their own home, but that usually means passing the same inspection.

The U.S. Consumer Product Safety Commission publishes dryer fire and carbon monoxide safety guidance. A carbon monoxide alarm is a smart addition after any gas appliance install.

Next step: call your gas utility or two licensed plumbers, measure the distance from the nearest gas pipe to the dryer spot, and ask each for an itemized quote that includes the permit and leak test.

Questions people ask

Does a gas dryer hookup need a permit?

Often yes when new gas pipe is added, though rules vary by city and state. Moving a dryer onto an existing valve may not require one, so call your local building department before work starts. Your plumber usually pulls the permit and schedules the inspection.

Is a gas dryer cheaper to run than an electric one?

It depends on your local gas and electricity rates. Compare your cost per therm to your cost per kilowatt-hour and the dryer's rated energy use before assuming it will pay back the hookup cost.

Can I use my old dryer vent with a gas dryer?

Often yes, if it is rigid or semi-rigid metal, reasonably short, clean and exits outdoors. Replace vinyl or foil duct and anything crushed, since combustion exhaust has to get outside.

How long does a gas dryer hookup take?

A short run with an existing outlet often takes a few hours. Longer runs, drilling through framing or waiting on an inspection can stretch the job to a day or two.

Do I need a carbon monoxide alarm with a gas dryer?

A CO alarm is a smart safety step with any fuel-burning appliance. Follow the manufacturer's placement instructions and local code, and look for a UL listing on the alarm.