Fix and Furrow
Advertise

Range Hood CFM Calculator: How Many CFM Do You Need?

Two sizing rules, what gas and induction change, and how long duct runs quietly cut airflow before you buy.

Save to Pinterest

We may earn a commission when you buy through links on this page. It never changes what we recommend. Learn more

Stainless steel wall-mounted range hood above a gas cooktop in a home kitchen
Photo: Chastity Cortijo on Unsplash

The short answer

For a standard 30-inch range, plan on roughly 250 to 350 CFM for electric or induction and 400 to 600 CFM for gas. Two rules get you there: 100 CFM per foot of cooktop width, or total burner BTUs divided by 100. Use the larger number, then size up if your duct run is long or has several elbows.

Typical cost
$200 to $2,500 for the hood; $300 to $1,500 more for new ducting and installation
Time needed
An evening to size it; one to two days to install
Skill level
Intermediate

Key points

  • Use 100 CFM per linear foot of cooktop for electric and induction, and total burner BTUs divided by 100 for gas, then take the larger result.
  • Island hoods are commonly sized at about 150 CFM per linear foot because cross-drafts pull the plume away from the hood.
  • Long duct runs and elbows can cut delivered airflow well below the number on the box, so count them before you buy.
  • Many jurisdictions require make-up air once a hood exceeds about 400 CFM, so ask your building department first.
  • Choose a hood ducted to the outdoors whenever you can, especially over gas.
In this guide
  1. What does CFM mean for a range hood, and why does it matter?
  2. Which sizing method should you use: linear foot or BTU?
  3. How do gas and induction cooktops change the number?
  4. Why do ductwork length and elbows reduce real airflow?
  5. Is a ducted or ductless range hood better?
  6. What is a good sone rating for a range hood?
  7. When do you need make-up air, and how can you tell?
  8. What does a range hood installation cost?
  9. How do you choose a range hood? A step-by-step checklist

Start with two numbers: your cooktop width in feet, and the total burner BTUs if you cook on gas. Multiply the width by 100 CFM, divide the BTUs by 100, and use the larger result. Then check your duct path, because it decides how much of that airflow you actually get.

What does CFM mean for a range hood, and why does it matter?

CFM stands for cubic feet per minute, and it measures how much air the hood moves. Too little and grease, steam, and smoke settle on cabinets and ceilings. Too much and you pay for a loud fan, pull heated or cooled air out of the house, and may trigger make-up air rules.

One catch: the number on the box comes from lab testing, typically with short, straight ductwork. Your kitchen won't match that, which is why the duct section below matters as much as the sizing math.

Which sizing method should you use: linear foot or BTU?

Use the linear foot rule for electric and induction, the BTU rule for gas, and take the larger number if you cook hard. Together they work as a simple range hood CFM calculator.

  • Linear foot rule: 100 CFM per foot of cooktop width for a wall-mounted hood. For an island range hood, the usual guidance is about 150 CFM per foot, because room drafts pull the plume sideways.
  • BTU rule: add up the maximum BTU rating of every burner, then divide by 100.
CooktopLinear foot ruleBTU rule
30-inch electricabout 250 CFMNot used
30-inch gas, about 40,000 BTU totalabout 250 CFMabout 400 CFM
36-inch gas, about 60,000 BTU totalabout 300 CFMabout 600 CFM
48-inch pro-style gas range, about 90,000 BTU totalabout 400 CFMabout 900 CFM

Look at how far apart the two methods land on gas. That gap is why single rules of thumb mislead people. Pull the burner BTUs from your range's spec sheet rather than guessing.

How do gas and induction cooktops change the number?

Gas pushes the number up, and induction lets you stay near the low end. Gas burners release heat and combustion byproducts into the room, and the high-output burners drive your BTU total. For a 30-inch gas range, 400 to 600 CFM is a sensible band. A pro-style gas range often calls for 600 or more.

An induction cooktop puts most of its heat into the pan, so the kitchen stays cooler and there's no flame. You still get grease, steam, and smoke from searing, though. The linear foot rule, which works out to roughly 250 to 350 CFM for most cooktops, fits well. Don't skip the hood just because there's no flame.

Check width and mounting height too. The hood should be at least as wide as the cooktop, and the manufacturer's manual sets the height above the surface. Gas often needs more clearance than electric, so follow the manual and your local code.

Why do ductwork length and elbows reduce real airflow?

Every foot of duct and every bend adds resistance, so a hood rated at 600 CFM can deliver far less through a long, twisty run. A common rule of thumb treats each 90-degree elbow as the equivalent of roughly 5 to 10 feet of straight duct, depending on duct size. Two elbows plus a 15-foot run can look like a 25- to 35-foot run to the fan.

  • Take the shortest, straightest path to the outdoors.
  • Use smooth rigid metal duct, not flexible foil, which has ridges that trap air and grease.
  • Match the duct size to the hood's outlet. Don't reduce it, and move up a size only if the manual allows.
  • Fit a wall cap with a damper that opens freely, and keep it clear of debris.

Cutting a new roof or exterior wall opening, hardwiring a new hood, or altering framing to route duct is work for a roofer, a licensed electrician, or a contractor, depending on the job. It often needs a permit.

Is a ducted or ductless range hood better?

A ducted hood is better because it removes heat, moisture, grease, and combustion gases from the house, while a ductless range hood only filters the air and sends it back. Recirculating models catch grease and some odor, but they can't remove humidity or combustion products.

Choose ductless only when there's no practical route outside, as in some condos and apartments. Plan to replace the charcoal filters on the manufacturer's schedule. Prices vary widely: ductless hoods commonly run $100 to $800, and ducted hoods about $200 to $2,500 or more. A new duct run through an exterior wall or roof adds roughly $300 to $1,500, driven by distance, wall material, and whether a roof penetration is involved.

We'd pick a ducted hood with 400 to 600 CFM, vented through rigid metal duct, for most homes with a gas range. Treat ductless as the fallback.

What is a good sone rating for a range hood?

Aim for about 3 sones or lower at the speed you'll use for everyday cooking; lower numbers are quieter. One sone is roughly a quiet refrigerator hum, and each doubling of the sone value is perceived as about twice as loud.

Medium-speed noise matters more than max-speed noise, since you'll rarely run the fan flat out. If you want high CFM without the roar, look at hoods with inline or remote blowers. They move the motor away from the kitchen, which lowers the noise you hear.

When do you need make-up air, and how can you tell?

You typically need make-up air once a hood exceeds about 400 CFM, though your local code decides. Many codes follow the International Residential Code on this point, but adoption varies, so ask your building department before you buy a powerful hood.

A big fan exhausts air from a house that's already fairly sealed. The house then pulls replacement air from wherever it can, including down the flue of a furnace or water heater. That's backdrafting, and it can bring carbon monoxide indoors.

Warning signs include a hard-to-open exterior door with the hood on high, whistling at window gaps, and weak performance despite correct ducting. A make-up air damper that opens when the hood runs often costs about $500 to $2,000 installed, depending on the system and how much ductwork it needs.

Permits depend on scope. A swap onto existing ducting often needs none, while new ducts, new circuits or a roof opening usually do. Cutting a roof opening is roofer work, new wiring belongs to a licensed electrician, and in a home built before 1978, opening painted walls falls under the EPA's lead-safe renovation rules.

What does a range hood installation cost?

Expect a range hood installation cost of $500 to $2,500 when you replace a hood and reuse existing ducting, and $1,500 to $5,000 or more when new ducting is involved. Hood style, duct length, and wall or roof work drive most of the spread.

ItemTypical U.S. range
Under-cabinet hood (unit)$150 to $700
Wall-mount chimney hood (unit)$400 to $2,000
Pro-style or large custom hood (unit)$1,500 to $5,000+
Labor, swap on existing duct$300 to $1,000
New duct through an exterior wall$500 to $1,500
Long run or roof exit$1,000 to $3,000+
Makeup air damper, installed$300 to $1,500

At the low end, an under-cabinet hood is the cheapest to buy, and a wall-mount chimney hood costs more. Prices also shift by region and by how much cabinetry, drywall, or siding has to be opened and repaired. Get quotes that itemize duct, cap, electrical, and permit fees separately.

How do you choose a range hood? A step-by-step checklist

Size the hood from your cooktop, check your duct path, then pick a quiet, listed model that fits both. Here's the order.

  1. Measure your cooktop width in feet and multiply by 100 CFM (150 for an island range hood).
  2. If you cook on gas, add the burner BTUs from the spec sheet and divide by 100. Use the larger of the two results.
  3. Map the duct path to the outdoors. Count the feet and the elbows, and add roughly 5 to 10 feet of equivalent length per elbow.
  4. Compare hoods using their performance charts at your duct length, and size the duct to the hood's outlet.
  5. Pick a hood that's quiet at medium speed, and confirm it carries a recognized safety listing such as UL.
  6. If the hood is above 400 CFM, call your building department about make-up air.
  7. If no outdoor route exists, buy a recirculating hood and budget for replacement filters.

Next step: tonight, measure the path from your cooktop to the nearest exterior wall or roof and write down the length and elbow count before you open a single product page.

Questions people ask

Can a range hood have too much CFM?

Yes. An oversized hood is louder, pulls more conditioned air out of the house, and can create a backdrafting risk in a tight home. Past roughly 400 CFM you may also need make-up air under local code.

What CFM do I need for a 36-inch gas range?

If the burners total about 60,000 BTU, the BTU rule gives roughly 600 CFM, while the linear foot rule gives only about 300. Use the larger number and confirm the BTU total on your range's spec sheet.

Is a 6-inch duct big enough for a 600 CFM hood?

Often not. Many hoods in that range specify 8-inch duct or larger, and a too-small duct chokes airflow and adds noise. Follow the outlet size and duct guidance in the hood's installation manual.

How wide should a range hood be compared with the cooktop?

At least as wide as the cooktop, and a few inches wider on each side is better for catching the plume. Wider coverage helps most with gas and with island installations where drafts pull smoke sideways.

Do I need a permit to install a new range hood duct?

It depends on your location and the scope of work. Cutting a new exterior wall or roof opening, hardwiring, or adding make-up air often involves a permit or inspection, so call your local building department first.

Sources and further reading

Elsewhere in Appliances